Mcquay model number tonnage.

McQuay Unit how many tons. Good afternoon everyone. Attached is a photo of a unit nameplate. Can anyone tell me how many tons of cooling this is? I am guessing it does not do any heating. Model #MPS050AE4DV1CYBV. Serial #FBOU081001739. Would you call this a self contained unit or a dx unit? Thanks. Reply. 07-27-2012, 08:31 PM #2.

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

McQuay ALS250AS27-ER10 I need the manual and service literature, thanks!! Reply . 10-01-2013, 07:54 PM #2. freonrick. View Profile View Forum Posts ... The model number is AGS351DP27NN-ER10, the compressors are HSA205QY13YA, thanks!! Reply . Quick Navigation Chillers Open Forum Top. Site Areas; Settings; Private Messages;Daikin AppliedMcQuay Offers the Widest Choice of ARI Certified, Ozone Safe Centrifugal Chillers NOTE: The upper capacity limit for ARI certification for water-cooled chillers is 2,500 tons. …Air Distributors Company, Inc. 913 Ulrich Ave Louisville, KY 40219 800-866-1210GROUP mcQUAY..P&Af'EX Inc. t36001ndustriaiParkB!vd.P.O.Box1551,Minneapolis,Mn.55440 . ND ... Available in three model types for horizontal and vertical unit arrangements: LSL VERTICAL UNIT ... -----NUMBER OF FANS IN STANDARD UNIT LYF-VENTILATING FAN SECTION LHD -HEATING AND VENTILATING UNIT

60Hz SEER10 R410A Cooling Only. Notes: The cooling condition: T1 condition: indoor side 27°C (80.6°F) DB, 19°C (60°F) WB, outdoor side 35°C (95°F) DB; The heating condition: indoor side 20°C (68°F) DB, 15°C (44.6°F) WB, outdoor side 7°C (42.8°F) DB. Sound level: measured at a point 1m in front of the unit at a height of 1.3m.

The optional factory-installed insulation of cold surfaces includes the evaporator and non-connection water head, suction piping, compressor inlet, and motor housing. Insulation is UL recognized (File # E55475). It is 3/4" thick ABS/PVC flexible foam with a skin. The K factor is 0.28 at 75°F.

McQuay Skyline OAH Series Installation And Maintenance Manual (36 pages) Skyline Air Handler Sizes 003-090. Brand: McQuay | Category: Air Handlers | Size: 2.26 MB.Model WMC, C Vintage 125 to 400 Tons (440 to 1400 kW) HFC-134a Refrigerant 50/60 Hz IOM 1210-1 Group: Chiller Part Number: IOM1210-1 Date: August 2014 Downloaded from www.Manualslib.com manuals search engineCommercial water source heat pumps can be applied to geothermal closed-circuit or open-well loops, or on a traditional boiler/tower loop system. These systems offer benefits ranging from low cost installation to the highest energy efficiency available in the market today. SmartSource® DOAS WSHP. 600 to 4,000 CFM. Product Info.Model Number Reference Guide Revision: April 2004. MODEL NUMBER INDEX BEGINNING MODEL PRODUCT PAGE FD, UD Deluxe System 2 1 ... Deluxe System 2 Tonnage Chart Tonnage 6 8 10 15 20 22 Air Cooled 075A 114A 125A 199A 245A 290A Water Cooled 086W 127W 138W 219W 267W 315WFor example, if you have the model number 24ACC636ABB3 from Carrier. That will include all units from 1.5 ton to 5 ton based on the cooling capacity. This will also include all SEER rating from 14 to 21 SEER. So the math is Model Number times Cooling Capacity times SEER rating (1 X 7) X 6 = 42. That is the minimal number of units a single model ...

To ascertain the tonnage of your Ruud HVAC system, inspect the model number. Focus on the second set of numbers within the model number. This figure will typically be divisible by 6 or 12, signifying the system's nominal BTU in the thousands. Given that one ton of air conditioning corresponds to 12,000 BTU, and using the equation 24 divided ...

1998 McQuay Air Cooled Chiller - 204 Ton Mfg: McQuay Model: ALS204AS12 Stock No. PSL01.15 Serial No. 58G8128101 1998 McQuay Air Cooled Liquid Chiller- 204 Ton. Model: ALS204AS12. S/N: 58G8128101. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 208 V, 881 amps, 60 Hz, 3 phase.

Available from 600 to 2500 tons, dual compressor chillers offer excellent full-load and part-load performance for increased energy savings. This industrial chiller occupies less floor space than having multiple single compressor chillers, while delivering the equivalent combined capacities. Using R-134a or R-513A refrigerant, these chillers ...Page 6 of 1 / Catalog 700 Performance Data - THC Horizontal Concealed (4-Pipe System) General Unit Data Conditions: 1 Cooling Capacity: Entering air temp.80oF (DB), 67oF (WB); Entering water temp.45oF, Leaving water temp. 55oF. 2 Heating Capacity: Entering air temp.70oF (DB); Entering water temp.180oF. Air Flow: Under dry coil conditions, fan speed high.Are you in need of replacement parts for your Lennox furnace? Finding the right parts can be a challenge, especially if you don’t know where to start. Fortunately, using the model ...Daikin Centrifugal Chiller McQuay Centrifugal Chiller WSC, TSC, HSC Unit Size 113 Critical Components MicroTech II Controls Main Controller, Large w/Display Signal Converter Board Guardistor Board Solenoid Valve, 4-Way Communication Options BACnet MS/TP RS232 Port only MODBUS RS485 Serial Board only LonWorks Serial Board only Filter Driers ...McQuay Water Cooled Chiller, year 1988, Model WHR070D, S/N 5TD0189100, 460 volt, 70 ton, 2 compressors.

With the WMC capacity range of 110 to 175 tons, it falls into two ASHRAE 90.1 efficiency requirements - below 150 tons and 150 tons & larger. Below 150 tons, the standard requires a full load and IPLV of 0.703 kW/ton (5.0 C.O.P.). The WMC chiller will easily meet these requirements.Low installation and operating costs. Plenum fans allow quieter operation. Modular construction from 20 to 130 tons. Controls flexibility—MicroTech® III controls for easy integration with the BAS of your choice. R-410A refrigerant allows higher efficiency (model SWP only) A self-contained AC unit from Daikin is an ideal option for multi ...The McQuay cabinet unit heater combines all the time proven quality features of McQuay units with a solid-state speed controller and a modern decorator styled cabinet to meet today's ever-increasing demands for attractive appearance, quiet performance, proven reliability and individual comfort a solution for your specific application. Contact your local McQuay sales office for computer selections of chillers to match your requirements. The following chart provides recommendations for the model choice for your application. Application McQuay Model Cooling, most hours at full load WSC – Single compressor chiller Serial Number- February, 1999 and later. AUB U 99 05 00148. Plant Identification Abbreviation. AUB = Auburn. U= Unit. Serial Number (build sequence) Week of Manufacture. Year of Manufacture. 08= 2008. 09= 2009 etc. WSHP; WCAX1,2, WCDX1,2, WCMS1,2 Size 019 Designs A, B Rev. J 01/16 RPL 1105106 / Page 4. Nomenclature. Model Number. WCDS 2 019 E Z ...The Skyline® air handling unit is designed to meet or exceed these demands. In addition to our patented construction, it features a durable, weathertight cabinet that promotes long life of your air handler. Skyline® also combats air contamination with micro-filtration, bacteria-defeating UV lights, mold-resistant drain pans, and anti ...The optimum model can be selected from an extensive product lineup for medium- to large-scale facilities for use in a variety of applications. Versatility. Daikin delivers energy efficiency to a wide range of process cooling applications with a lineup featuring a full range of capacities for all conditions and cooling requirements. ...

15-20 Ton MCQUAY AC Unit: Model #: N/A: Serial #: FB0402030023603: Year Built: 0: Location: North Carolina: ... $3,000.00: Description. 1 used McQuay for sale, approximately 15 - 20 Ton, 2000 to 6000 CFM. model RDS708BY air conditioning unit. Overall Dimmensions 68'' wide x 52'' high. 5HP Evaporator fan motor. All loads 460 volt. Additional ...

SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200Manufacturer McQuay. Tonnage 50. Air or Water Air Cooled. Refrigerant R-410A. Voltage 208. Phase 3. Hz 60. Model Number AGZ050EDSEMUG00. Serial Number STNU190100221.Industry-LeadingTechnologies. To meet and exceed demanding building performance criteria, our rooftop systems integrate advanced HVAC technologies including: Variable speed inverter compressor. Variable speed heat pump. Direct-drive fans with variable speed ECM or VFD motors. Energy recovery wheel. Outdoor air monitor. Modulating hot gas …Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one for a 3 ton system. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the "RLA" rating on the data plate.Equipment Description. Used McQuay ACR070A827-ER10 Air Cooled Water Chiller with: Air cooled water chiller unit. Maximum relief pressure: 450 PSIG. High side design pressure: 450 PSIG. Low side design pressure: 150 PSIG. Refrigerant: 22. Total charge: 20 pounds. Circuit 1 charge: 60 pounds.How to determine the date of production/manufacture or age of Daikin® brand HVAC Systems. The industry average service design life for most forced air furnaces is 15-20 years, and the industry average service design life for most air conditioning condensing units is 10-15 years. The average service design life of boilers can vary from as ...All fields. description: 2004 McQuay Air Cooled Chiller 130 Ton. Model AGZ-130BS. S/N STNE04109521, 460 /60/3. This chiller is factory new used only for in house testing. Has 6 scroll compressors and is capable of producing glycol at 0 F. name: 2004 McQuay Air Cooled Chiller 130 Ton Model AGZ-130BS. From genemco.comManufacturer McQuay. Tonnage 500. Air or Water Water Cooled. Refrigerant R-134a. Voltage 460. Phase 3. Hz 60. Model Number WME0501SBSNA. Serial Number STNU180500021.

%PDF-1.6 %âãÏÓ 1371 0 obj > endobj 1386 0 obj >/Filter/FlateDecode/ID[2C57F1C273E3CA498FA7F38C6B63FC5F>]/Index[1371 126]/Info 1370 0 R/Length 97/Prev 1518284/Root ...

McQuay Horizontal Water Source Heat Pump - 1/2 to 6 Ton - Free download as PDF File (.pdf), Text File (.txt) or read online for free.

All McQuay low and medium pressure central station air handling units (sizes 114 through 172) have factory installed, internally mounted motors and drives .. This means that ex­ pensive jobsite coordination and field mounting of motors has been eliminated .. Motor life is increased with the McQuay air handling unitsThese links wiIl lead to yóu purchase a próduct from another cómpany. Mcquay Chiller Model Numbers Serial Numbers And How Question Posted By Francisco the Building Engineer on May 3, 2011 Refer to the manufacturers website for their HVAC nomenclature of the model number and serial numbers and how those numbers correspond to the tonnage and other technical data.Page 36 3-1/2 x No. of DX rows *DX coil configuration (S = Standard, L = Large) is identified by the 8th digit of the RPS/RDT or RFS model number, found on the unit nameplate. For example, DX = L for unit model number RFSO6OCLY. Page 37: Refrigeration Service Valves The unit is shipped with all refrigeration service valves closed.YORKHVAC Technician: Steven S. McQuay - WSC087-BAAA Water-Cooled (Semi-Hermetic) - 460V / 480V / 3-Phase / 60Hz - 400 Ton Capacity. Ask Your Own HVAC Question. WSC087-BAABC is the model number.You can find the Trane tonnage and SEER in the 5 th, 7 th and 8 th characters of the Trane model number. The 5 th character represents SEER in a single number; the 7 th and 8 th characters, also numbers, show the tonnage code.. The Trane model number nomenclature for central air conditioners and heat pumps is explained below in this Trane model lookup.Available from 300 to 1200 tons, single compressor centrifugal chillers offer excellent full-load and part-load performance for increased energy savings and an excellent life cycle return on your investment. Using R-134a or R513A refrigerant, these chillers easily integrate with building automation systems, are seismic compliant, quiet and have ...Find many great new & used machinery deals and get the best price for 225 Ton, McQuay #AGS250DSHNN-ER10, Air Cooled Chiller at Surplus Record. ... > Show Seller's Phone Number 737-258-8446 Let the seller know you found their listing on Surplus Record! ... McQuay Air Cooled Water Chiller Unit. Model: AGS250B27-ER10. Serial No: STNU040600021 ...WHERE'S MY MODEL NUMBER? All appliances have a model number and a serial number tag located on the appliance. Generally they are available for the customer to find quickly. ... You're reviewing: 055371705 Daikin-McQuay ALP027C CKT 1 Condenser Coil Your Rating. Quality. 1 star 2 stars 3 stars 4 stars 5 stars. Nickname. Summary. Review. Submit ...15-20 Ton MCQUAY AC Unit: Model #: N/A: Serial #: FB0402030023603: Year Built: 0: Location: North Carolina: ... $3,000.00: Description. 1 used McQuay for sale, approximately 15 - 20 Ton, 2000 to 6000 CFM. model RDS708BY air conditioning unit. Overall Dimmensions 68'' wide x 52'' high. 5HP Evaporator fan motor. All loads 460 volt. Additional ...Buick car models come in all shapes and price ranges. See pictures and learn about the specs, features and history of Buick car models. Advertisement Buick models come in all shape...

Manufacturer McQuay. Tonnage 50. Air or Water Air Cooled. Refrigerant R-410A. Voltage 208. Phase 3. Hz 60. Model Number AGZ050EDSEMUG00. Serial Number STNU190100221.Ruby: 972-777-6574. Jamey: 214-755-8019. [email protected]. Our Location. Our main service facility is located in Dallas, Texas. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Surplus Group. 2121 Santa Anna Ave. Suite 100.For Assistance: Give A Missed Call: @ 9210188999 Call Our Customer Support: 011-40319300 / 1860 180 3900 or Write To Us at: [email protected] For Refrigeration Products:Instagram:https://instagram. 4001 bellaire blvd1975 cleveland indian rosterbutler pa scanner updatesspanish 1 semester 2 final exam answer key For Mitsubishi, you should look near the end of the model number. It will be a two-digit number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 18 divided by 12 equals 1.5, so the data plate below indicates the system is 1-1/2 tons.McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors of dlp 1035 spectrumseafood market savannah letters to McQuayService and refer to the model number and the serial number of the unit as stamped on the serial plate attached to the unit. If replacement parts are required, give ... New York 13021-9030 • 800-432-1342 • www.mcquay.com IM 218-6 Pg 2 of 2 (12-02) ©2002 McQuay International This document contains the most current product ...Download 140 McQuay Air Handlers PDF manuals. User manuals, McQuay Air Handlers Operating guides and Service manuals. asbury park nj obituaries ©2007 McQuay International. Illustrations and data cover the McQuay International product at the time of publication and we ... Figure 1, Model ACZ 033, 30-ton Condensing Unit . Catalog ACZ-AGZB1-1 5 Design Features The McQuay air-cooled, scroll compressor units are a product of the McQuay commitment to offer quiet, reliable, energy efficient ...Often used in conjunction with coils in air handlers, chillers receive warm fluid from the air handler coil or process load, lower the temperature of the fluid, then a pump returns the fluid to the air handler coil or process. Chillers come in two main varieties: air-cooled and water-cooled. An air cooled chiller rejects the heat absorbed from ...McQuay Horizontal Water Source Heat Pump - 1/2 to 6 Ton - Free download as PDF File (.pdf), Text File (.txt) or read online for free.